Whatever your application, our Contura
switches deliver the performance you demand — and the flexibility you
need. There’s no challenge these sealed switches can’t help you address.
Especially since they’re IP66/IP68 certified, UL1500 recognized, and
able to withstand temperatures from -40°C to +85°C. Never have such
rugged switches been available in such attractive packages. Adazzling
array of light, lens and legend options on several actuator styles,
plus countless circuit combinations, and valuable accessories, make
our Contura switches the ideal choice. |
|
Maximum
Design Options with minimum inventories
Panel redesign is a snap, requiring no tooling
change, with our removable interchangeable actuators. A unique balance
between aesthetics and functionality.
Seals
out water, dust and debri
Dual seal protection locks out elements. Certified
to IP66/IP68.
Clean
Connections
Offered in both eight and ten terminal base options.AMP
& Packard compatible connectors available.
Optional
Panel Seal
Prevents water/dust egress behind panel.
Multiple
Lighting Options
Incandescent lamps & LED illumination. Our LED
illumination is offered in a wide array of light intensities, colors,
as well as dual level illumination and flashing options.
Withstands
Extreme Temperatures
Roller pin mechanism eliminates need for lubricants,
so it can withstand from 40℃ to +85℃.
|
|
 |
V-Series switches offer countless
unique options including choices for ratings, colors, illuminations
and symbols. These switches feature removable actuators in a choice
of actuator styles and colors, and are available in single or double
pole configurations. The V-Series switches can be illuminated with either
square, oval and/or bar shaped lenses. |
 |

The Contura II actuators are constructed of thermoplastic polycarbonate,
and are offeredwith either a hard nylon overlay, or a “soft-touch” elastomer
overlay. The Contura II incor-porates an aesthetic design of two rows
of raised “bumps” on the top and bottom of the rocker. |
 |

The Contura III actuators are constructed of thermoplastic polycarbonate,
and are offered with either a hard nylon over lay, or a “soft-touch”
elastomer overlay. The Contura III incorporates three rows of bars on
the top and bottom of the rocker. |
 |

The Contura IV’s “Shape to create a Shape” actuator suports the designer,
by working with the curves, contours and advanced styling of the latest
panel designs, flowing with these advanced curves and radii. This actuator
style fits on the Contura II & III flush bracket/bezel. |
 |

The symmetrically curved Contura V actuator provides the perfect complement
to the Contura IV’s “Shape to create a Shape”design concept. It can
be mounted in between two Contura IV’s, by itself, or in groups. This
actuator style is available with all flush style mounting brackets. |
 |

The raised bracket/bezel on the Contura X helps prevent inadvertent
actuation of the rocker, as well as preventing debris from being trapped
under the actuator. The conventionally designed actuators are available
with one-piece bar lenses, or square lenses in either one or two part
construction with backlit legends, for increased durability of lens
symbols. |
 |

The raised bracket/bezel on the Contura XI helps prevent inadvertent
actuation of the rocker, as well as preventing debris from being trapped
under the actuator. The actuators are available with onepiece bar lenses,
or square lenses in either one or two part construction with backlit
legends, for increased durability of lens symbols. |
 |

The Contura XII version incorporates a paddle style handle on the raised
bracket/bezel, also used in the Contura X and XI switch. The contoured
handle design provides intuitive recognition and ease of operation for
a variety of transportation related applications, and is available with
all Contura X and XI lens and legend offerings. |
 |

The Illuminated Plug is offered with removable/ replaceable lamps, Contura
II, V and X styling, and LED illumination. As a critical safety feature,
it’s illumination alerts the operator of essential system functions
or malfunctions like: oil pressure, high temperature, transmission or
other fluid levels, parking brake, or general system malfunction. |
|
 |
Carling Technologies also offers
many V-Series accessories including connectors, mounting panels, hole
plugs, panel seals, and actuator removal tools. |
|
 |
 |
| Electrical |
| Contact Rating |
.4VA@ 24VDC (MAX) resistive 15 amps, 125 VAC
10 amps, 250 VAC
1/2 HP125-250 VAC
20 amps, 4-14 VDC
15 amps, 15-28 VDC
10A14VT
6A125 VAC L |
| Dielectric Strength |
1500 Volts RMS |
| Insulation Resistance |
50 Megohms |
| Initial Contact Resistance |
10milliohms max. @4VDC |
| Initial Contact Resistance Life |
50,000- 100,000 cycles circuit dependent |
| Contacts |
Silver cad-oxide, silver tin-oxide, fine silver |
| Terminals |
Brass or copper/silver plate 1/4”(6.3mm) Quick
Connect terminations standard. Solder lug, Wire Lead |
| Mechanical |
| Endurance |
150,000 cycles minimum |
| Physical |
| Lighted |
Incandescent - rated 10,000 hours
Neon - rated 25,000 hours
LED - rated 100,000 hours 1/2 life (LED is internally ballasted for
voltages to 24 VDC) |
| Seals |
Internal
Optional external gasket panel seal |
| Base |
Polyester blend rated to 125C with a Random
ULflammability rating of 94 V-O. |
| Contura II , III , IV , V |
| Actuator |
Hard Surface: Basic actuator structure molded of thermoplastic
polycarbonate with a hard Nylon 66 thermoplastic surface overlay.
Soft Surface: Basic actuator structure molded of thermoplastic polycarbonate
with an elastomer overlay. |
| Contura X , XI , XII |
| Actuator, VP |
Nylon 66 Reinforced rated to 105℃ |
| Lens |
Polycarbonate rated at 100℃ |
| Actuator Travel (Angular Displacement)
|
| 2 position |
18℃ |
| 3 positions |
9℃ from center |
| Mounting Specifications |
| Panel Thickness Range |
| # of gaskets |
Acceptable Panel Thickness |
| 0 |
.030 to .250 (.76mm to 4.76mm) |
| 1 |
.030 to .109 & .147 to .157
(.76 to 2.77mm & 3.73 to 3.98mm) |
| Recommended: No gasket with panel thickness of .032,
.062, .093, .125,.187 or .250 |
|
| Agency Certifications |
 |
| Environmental |
| Environmental |
Sealed version: IP68, in accordance
with IEC 529, BS 5490, DIN 400 50 & NFC 20 010. This rating applies
to front panel components and signifies protection against dust and
the prolonged effects of immersion under pressure. The standard test
for mmersion under pressure requires submersion under one meter of
water for 30 minutes. The V-Series switch has exceeded these parameters,
having been actuated and illuminated during submersion.
NOTE: Sealed switch with optionalpanel gasket will meet IP67 rating.
|
| Corrosion |
Flowing Mixed Gas (FMG)
Class III 3 year accelerated exposure per ASTM B-827, B-845
Silver and gold contacts |
| Physical Operating Temperature |
-40℃ to + 85℃ |
| Vibration 1 |
Per Mil-Std 202F, Method 204D Test Condition A0.06
DAor 10G’s 10-500 Hz. Tested with VCH connector. Test criteria - No
loss of circuit during test and pre and post test contact resistance.
|
| Vibration 2 |
Resonance search
24-50 Hz 0.40 DA
50-2000 ±10 G’s peak
Results Horizontal Axis 3-5 G’s max. |
| |
Random |
|
| |
24 Hz
60 Hz
100Hz
200Hz
2000Hz |
0.06PSD-Gsq/Hz
0.50
0.05
0.025
0.025 |
| |
No loss of circuit during test;
<10μ seconds chatter. |
| Shock |
Per Mil-Std 202F, Method 213B,
Test Condition K @ 30G’s. Tested with VCH connector. Test criteria
- No loss of circuit during test, pre and post test contact resistance.
|
| Salt Spray |
Per Mil-Std 202F, Method 101D, Test Condition A, 48
Hrs. Sealed version only. |
| Dust |
Per Mil-Std 810C, Method 510.2 Air Velocity 300 ±200
Feet/Min, Test Duration 16 Hrs. |
| Thermal Shock |
Per Mil-Std 202F, Method 107F,
Test Condition A, -55℃ to 85℃. Test criteria - pre and post test
contact resistance |
| Moisture Resistance |
Per Mil-Std 202F, Method 106F, Test Criteria - pre
and post test contact resistance |
| Ignition Protection |
All Contura switches with sealed construction meet
the requirements of UL1500/ISO8846 for ignition protection, in addition
to conformance with EC directive 94/25/EC for marine products. |
|
|
 |
| |
|